Connecting to ExperTune Advanced PID Optimizer or PID Tuner

What brand of controller will you be working with? Click on it from the list below. If it is not listed here, call Scott Friedemann at +1 (262) 369 7711.

PlantTriage uses either OPC or OPC HDA connections. ExperTune software is certified OPC Compliant.


Connections for DCSs and single loop controllers

  • Preferred method: ExperTune Setup Wizards — Works with your OPC (or DDE) server. Simply enter a few addresses and ExperTune does all the work of setting up your loop for analysis, optimization and tuning.
  • Do you have a historian connected to your control system? YES
  • Do you have the process variable and controller output data in an ASCII file? YES
  • Get controller PV and CO data using voltage, thermocouple, RTD. YES

Go back to choose your controller
Request quote


Connecting to ABB Mod 300

  • Use the Mod 300 DDE server for the easiest connection to ExperTune via DDE. Use Application|Topic of MOD|REALTIME if the Mod 300 DDE server is running on the same PC or \\YourNodeName\NDDE$|MOD$REALTIME if net DDE.
  • Or, do you have a historian connected to your Mod 300 system? YES
  • Or, do you have the process variable and controller output data in an ASCII file? YES
  • Or, get controller PV and CO data using voltage, thermocouple, RTD. YES

Go back to choose your controller
Request quote


ExperTune for Bailey

To connect to a Bailey DCS, use ExperTune's OPC connection combined with a Bailey driver from RoviSys. Just plug into the CIU. ExperTune's setup Wizard for Bailey (released October 1998) makes connecting super-easy using the RoviSys driver.

The RoviSys driver supports these Bailey interfaces:

  • Loop Command Series Systems: NCIC01
  • NETWORK 90 Systems: IMCPM03, NCIU01, NCIU02, NCIU03, INPCI01, INPCI02
  • INFI 90 Systems: NCIU04, INICI01, INICI03, INICI12. (INICI03 and INICI12 interfaces added Dec 2000)
Or use OPC HDA to analyze data collected in your historian.

Go back to choose your controller
Request quote

Connecting to Fisher DeltaV

  • Use the DeltaV OPC Server and connect via ExperTune's OPC PID Tuner. Using ExperTune's setup wizard.
  • Or use OPC HDA to analyze data collected in your historian.
  • Or use DDE: ExperTune's DDE PID Analyzer/Tuner supports an easy connection to Fisher's DeltaV system (note: OPC is preferred connection). To connect to DeltaV:
    1. Start \DeltaV\Fix32\Dmdde.exe.
    2. Use Dmdde|data for the application|topic name in ExperTune.
    3. Place an 'X' in Use Hot Links and Unique Write Locations. Enter your Node:Tag.Field information in each of the fields for the items.
    4. Any item that is titled as a send item, such as SP to send, should use an A_ field instead of an F_ field. For example, an SP item may be MyNode:ReactorTemp/pid1/sp.f_cv and the SP to send item MyNode:ReactorTemp/pid1/sp.a_cv.

Go back to choose your controller
Request quote


Connecting to Fisher PROVOX

  • Connect to PROVOX using ExperTune's OPC connection Wizard and the PRODirect OPC Server from TIPS. ExperTune's PROVOX wizard makes connecting to Fisher PROVOX a snap using the TIPS OPC Server. Alternatively you can use Emerson's OPC Server.
  • Or use OPC HDA to analyze data collected in your historian.
  • Do you have the process variable and controller output data in an ASCII file? YES

Go back to choose your controller
Request quote


Connecting to Foxboro I/A

Go back to choose your controller
Request quote


Connecting to Honeywell Experion or PlantScape

Connect using ExperTune's OPC connection Wizard and the Honeywell OPC server included with Experion or Plantscape. ExperTune's Honeywell wizard makes connecting to Experion or Plantscape a snap. It supports remote OPC over your network. Simply enter in the:

  • Computer name (on the network where Experion resides). Click the 'B' button to browse the network. If the server is in this computer, leave the field blank.
  • Enter the Control Module PID Block name for your loop.
And ExperTune will connect up!

Technical note: To write to SP, CO, and Mode, the mode attribute (listed as 'MD Attr') has to be set to Program in Station on the PID faceplate.

Or use OPC HDA to analyze data collected in your historian.

Go back to choose your controller
Request quote


Connecting to Honeywell TDC

Preferred connection method to Honeywell TDC systems:

  • APP: If you have an Application Processing Platform (APP) then you can connect to the TDC-3000 via OPC using "Honeywell TPN Server". The APP Node comes with Honeywell TPN Server. Although used by some, Honeywell does not recommend running TPN server on a GUS.
  • Via a historian. You can connect using OPC HDA.

Please ask us for a quotation for ExperTune PID Analyzer for use with your Honeywell TDC system and we will include a 26 page white paper that describes how to set up your TDC system for OPC or DDE communication. Call us at +1 (262) 369 7711.

Alternative connection methods to Honeywell TDC Systems:

  • GUS: If you have a Global User Station (GUS) and "Honeywell DDE Server" software: Use DDE to connect ExperTune software to your controller. GUS does not support writing back to the loop. Install and run ExperTune software either on the server or on a remote machine.
  • Have the process variable and controller output data in an ASCII file? YES
  • Or, we can supply you with hardware to get controller PV and CO data using voltage, thermocouple, RTD inputs into your PC or laptop. YES

Go back to choose your controller
Request quote


Connecting to Rosemount RS3

  • Run the Rosemount Network Interface (RNI). Connect to RNI using Intellution's iFIX (or The FIX). Use DDE in iFIX or The FIX to connect to ExperTune.
  • Or, do you have a historian connected to your control system? YES
  • Or, do you have the process variable and controller output data in an ASCII file? YES
  • Or, get controller PV and CO data using voltage, thermocouple, RTD. YES

Go back to choose your controller
Request quote


Connecting to Siemens Moore APACS and APACS+

To connect to an APACS system, use either of these preferred methods:

Or you can use ExperTune DDE connection combined with APACS DDE Server or the MYCROADVANTAGE DDE server. ExperTune's setup Wizard for APACS (released October 1998) makes connecting super-easy.

Go back to choose your controller
Request quote


Connecting to Siemens Moore Procidia

Connect to Procidia using ExperTune's Procidia Modbus OPC connection Wizard (released Jan 2001).

Go back to choose your controller
Request quote


Connecting to Moore 353, 352P

To connect to a Moore 353 or 352P use Moore's Modbus OPC Server for the Model 353. It is identified as Model iWARE-OPC-V1.00. (Both LIL and Modbus OPC servers are included).

Go back to choose your controller
Request quote


Connecting to Yokogawa Centum

There are several easy ways to connect ExperTune to Yokogawa Centum.

  • ExperTune OPC communication option combined with Yokogawa's OPC Server. This is the fastest and the recommended way to connect to Centum.
  • Or use OPC HDA to analyze data collected in your historian.
  • ExperTune DDE communication option combined with a Yokogawa's DDE server. Communication with this method may not support hot links and may be slow.
  • ExperTune's Multi-channel trending and A/D Converter to read voltage signals direct from I/O.

Go back to choose your controller
Request quote



Connections for AB, GE, Modicon, Moore and TI

  • Preferred method: ExperTune Setup Wizards — Works with your OPC or DDE server or driver. Simply enter a few addresses and ExperTune does all the work of setting up your loop for analysis, optimization and tuning.
  • If you have a plant historian available, use OPC HDA to analyze data collected in your historian.
  • If you are running an MMI (like Wonderware or Intellution) and want to run ExperTune on the same machine use DDE or OPC
  • Or, use ExperTune's GES-200 to get controller PV and CO data using voltage, thermocouple, RTD.
  • Or, get controller PV and CO data into an ASCII file (.csv or .txt) and use the ASCII import option.

Go back to choose your controller
Request quote


OPC

OPC or OLE for Process Control is a standard set by the OPC Foundation for fast and easy connections to controllers. Use the OPC data built into ExperTune to connect to any OPC server. ExperTune supports both OPC and OPC HDA (Advanced only) connections. ExperTune Inc, is an OPC Foundation Member.

Link to OPC Overview from the OPC Foundation.

OPC Setup Wizards — Works with your OPC server. Simply enter a few addresses and ExperTune does all the work of setting up your loop for analysis, optimization and tuning.

View and/or download the complete list of ExperTune Setup Wizards

FREE download: Use ExperTune's Test Client for OPC to verify communication with your OPC Server. Once verified, you are assured ExperTune will connect and communicate successfully.

Download Test Client for OPC Now (2.6 Mb).

OPC Servers are available from:

Go back to choose your controller
Request quote


OPC HDA

OPC or OLE for Process Control is a standard set by the OPC Foundation for fast and easy connections to controllers. ExperTune embraces two standards established by the OPC foundation:

  • OPC DA or Data Access - for accessing data real-time
  • OPC HDA or Historical Data Access - accesses data on historians
With OPC HDA, you can use ExperTune's:
  • Use ExperTune's PID Tuner to data mine, tune, and analyze data from the past. (Requires ExperTune PID Tuner Advanced Option)
  • PlantTriage now will monitor the performance of your plant directly from the Historian data. By using the historian's data directly, PlantTriage doesn't need to extract real time data directly from the control system. This eliminates potential stress on the control system.

ExperTune PlantTriage's and PID Tuner use OPC HDA to make this possible. Interfaces to these historians:

  • OSI PI Historian
  • AspenTech InfoPlus.21
  • Honeywell PHD
  • Invensys AIM*Historian
  • Any historian supporting OPC HDA
HDA stands for Historical Data Access, a new standard from the OPC Foundation. Many plants have a historian, like OSI's PI system. With OPC HDA access, PlantTriage performs all of its assessments from data mined directly from that historian.

ExperTune Inc, is an OPC Foundation Member.

Link to OPC Overview from the OPC Foundation.

Go back to choose your controller
Request quote


DDE

Use the DDE (Windows Dynamic Data Exchange) linking built into ExperTune DDE to connect to any MMI or DDE server. DDE is an older standard that has for the most part been replaced by OPC.

ExperTune Setup Wizards — Works with your OPC (or DDE) server. Simply enter a few addresses and ExperTune does all the work of setting up your loop for analysis, optimization, and tuning.

OPC Performance Issues, including benefits over DDE PDF from the OPC Foundation.

OPC Servers are available from:

Go back to choose your controller
Request quote


ASCII

ExperTune PID Analyzer with the ASCII option imports multi-channel plant data from ASCII files. The ASCII option handles virtually any type of ASCII columnar data. Collect your PV, CO, and other variables, at the sample interval of your controller.

Go back to choose your controller
Request quote


A/D Converter or GES-200

GES200 The A/D Converter or GES-200 is a complete data acquisition system. It reads voltage, current or RTD signals, displayed real-time in Windows. It saves PV and CO data to disk for tuning and analysis off-line. It includes:

  • GES-200 box containing:
    • Two input modules with 16 bit resolution and 1,500 V of isolation. Each input is configured for your choice of: Voltage: ± 150mV, 500mV, 1V, 5V, 10V, 50V
    • 4-channel backplane with RS-232 (or RS-485) interface to IBM PC compatibles or laptops through the serial port.
  • 50 ms anti-aliasing filter.
  • RS-232 cable for connection of GES-200 to your IBM PC or compatible.
  • Two 6 ft signal cables with "mini-grabber" clips for easy connection to plant I/O. Dual banana jacks on the other end connect the GES-200.
  • Plug-in power supply. Input: 120VAC. Output: +5V DC at 1.5A.
  • Configuration software for input modules.

Thermocouple and RTD inputs available.

The GES-200 uses the serial port of your PC or laptop, there is no board to install in the PC.

Input impedance of standard modules (6B12) is 1M ohm. The input impedance of the thermocouple modules (6B11) is 100M ohms.

Each module includes a 50 ms anti-aliasing filter, resulting in normal mode rejection of interference from frequencies 60Hz and higher.

To use with thermocouples, simply connect the GES-200 input in parallel with your thermocouple input on your controller (assuming your controller input impedance is 20k ohms or more).

Go back to choose your controller